HVAC Zone Valves

Available81 products

HVAC zone valves, also called hydronic zone valves, control the flow of water or steam through the different zones of a hydronic HVAC system. This increases efficiency by allowing users to regulate the temperature in specific areas of a building.

2-Way NPT Connection Zone Valves

2-Way NPT Connection Zone Valves
Two-way NPT (National Pipe Thread) connection zone valves have two connection points and are fully open or closed to control the flow of fluids through them. They feature NPT connections that are quick to install and remove, allowing for maintenance and repair. They are commonly used to control the flow of heating and cooling fluid to specific areas or zones of a building.

General Purpose Applications

Pneumatic Spring Return Actuator

Loading...

Electric Non-Spring Return Actuator with On/Off Signal

Loading...

Electric Non-Spring Return Actuator with Floating Signal

Loading...

Electric Spring Return Actuator with On/Off Signal

Loading...

Geothermal Applications

Electric Non-Spring Return Actuator with On/Off Signal

Loading...

2-Way Sweat Connection Zone Valves

2-Way Sweat Connection Zone Valves
Two-way sweat connection zone valves have two sweat connection points and control water and steam flowing through them. They feature sweat connections that create a permanent joint and require solder training and equipment to create a secure seal.

General Purpose Valve

Electric Non-Spring Return Actuator with On/Off Signal

Loading...

Electric Spring Return Actuator with On/Off Signal

Loading...

Geothermal Valve

Electric Non-Spring Return Actuator with On/Off Signal

Loading...

3-Way NPT Connection Zone Valves

3-Way NPT Connection Zone Valves

Three-way NPT (National Pipe Thread) zone valves have three connection points and direct steam and water flowing through them. Three-way valves allow for the diverting of flow, one input to two outputs, or the mixing of flows, two inputs to one output. They feature NPT connections that are quick to install and remove, allowing for easy maintenance and repair.

General Purpose Valve

Pneumatic Spring Return Actuator

Loading...

Electric Non-Spring Return Actuator with On/Off Signal

Loading...

Geothermal Valve

Electric Non-Spring Return Actuator with On/Off Signal

Loading...

3-Way Sweat Connection Zone Valves

3-Way Sweat Connection Zone Valves
Three-way sweat connection zone valves have three sweat connection points and control water and steam flowing through them. Three-way valves allow for the diverting of flow, one input to two outputs, or the mixing of flows, two inputs to one output. They feature sweat connections that create a permanent joint and require solder training and equipment to create a secure seal.

General Purpose Valve

Electric Non-Spring Return Actuator with On/Off Signal

Loading...

Geothermal Valve

Electric Non-Spring Return Actuator with On/Off Signal

Loading...
Note: Product availability is real-time basis and adjusted continuously. The product will be reserved for you when you complete your order.
Back to Top