Hazardous Location Sealing Fittings

Available168 products

Sealing fittings join pieces of heavy-wall RMC and medium-wall IMC metal conduit together or to enclosures and hold a seal around wire within the conduit. They minimize the passage of gases and vapors and prevent the passage of flames from one electrical installation to another through the conduit system. They also restrict explosions to the sealed-off enclosure and prevent pressure from piling up in the conduit system. These fittings are used in hazardous industrial locations, such as petroleum refineries, gasoline storage areas, and petrochemical facilities.

Vertical and Horizontal Sealing Fittings

Vertical and Horizontal Sealing Fittings
Sealing fittings join pieces of RMC and IMC conduit together and can be used in vertical or horizontal orientations. These fittings hold a seal around wire within the conduit to minimize the passage of gases and vapors, prevent the passage of flames from one electrical installation to another, restrict explosions to the sealed-off enclosure, and prevent pressure from piling up in the conduit system. They’re suitable for use in hazardous locations where flammable gases, vapors, powdered metals, or dust is present.

Female to Female Threaded Ends

Loading...

Vertical and Horizontal Sealing Fitting - 25% Fill

Vertical and Horizontal Sealing Fitting - 25% Fill
Sealing fittings join pieces of RMC and IMC conduit together and can be used in vertical or horizontal orientations. They have a 25% fill and conductors should not exceed this amount of space within the fittings so they can be sealed properly. These fittings hold a seal around wire within the conduit to minimize the passage of gases and vapors, prevent the passage of flames from one electrical installation to another, restrict explosions to the sealed-off enclosure, and prevent pressure from piling up in the conduit system. They’re suitable for use in hazardous locations where flammable gases, vapors, powdered metals, or dust is present.

Female to Female Threaded Ends

Loading...

Male to Female Threaded Ends

Loading...

Vertical Sealing Fittings - 25% Fill

Vertical Sealing Fittings - 25% Fill
Sealing fittings join pieces of RMC and IMC conduit together and can be used in a vertical orientation only. They have a 25% fill and conductors should not exceed this amount of space within the fittings so they can be sealed properly. These fittings hold a seal around wire within the conduit to minimize the passage of gases and vapors, prevent the passage of flames from one electrical installation to another, restrict explosions to the sealed-off enclosure, and prevent pressure from piling up in the conduit system. They’re suitable for use in hazardous locations where flammable gases, vapors, powdered metals, or dust is present.

Female to Female Threaded Ends

Loading...

Male to Female Threaded Ends

Loading...

Vertical Sealing Fittings with Drain - 25% Fill

Vertical Sealing Fittings with Drain - 25% Fill
Sealing fittings include a drain that prevents the accumulation of condensate above the seal. These fittings join pieces of RMC and IMC conduit together and can be used in a vertical orientation only. They have a 25% fill and conductors should not exceed this amount of space within the fittings so they can be sealed properly. These fittings hold a seal around wire within the conduit to minimize the passage of gases and vapors, prevent the passage of flames from one electrical installation to another, restrict explosions to the sealed-off enclosure, and prevent pressure from piling up in the conduit system. They’re suitable for use in hazardous locations where flammable gases, vapors, powdered metals, or dust is present.

Female Threaded Ends

Loading...

Male Threaded Ends

Loading...

Vertical and Horizontal Sealing Fitting - 40% Fill

Vertical and Horizontal Sealing Fitting - 40% Fill
Sealing fittings join pieces of RMC and IMC conduit together and can be used in vertical or horizontal orientations. They have a 40% fill and conductors should not exceed this amount of space within the fittings so they can be sealed properly. These fittings hold a seal around wire within the conduit to minimize the passage of gases and vapors, prevent the passage of flames from one electrical installation to another, restrict explosions to the sealed-off enclosure, and prevent pressure from piling up in the conduit system. They’re suitable for use in hazardous locations where flammable gases, vapors, powdered metals, or dust is present.

Female Threaded Ends

Loading...

Vertical Sealing Fitting - 40% Fill

Vertical Sealing Fitting - 40% Fill
Sealing fittings join pieces of RMC and IMC conduit together and can be used in a vertical orientation only. They have a 40% fill and conductors should not exceed this amount of space within the fittings so they can be sealed properly. These fittings hold a seal around wire within the conduit to minimize the passage of gases and vapors, prevent the passage of flames from one electrical installation to another, restrict explosions to the sealed-off enclosure, and prevent pressure from piling up in the conduit system. They’re suitable for use in hazardous locations where flammable gases, vapors, powdered metals, or dust is present.

Female Threaded Ends

Loading...

Vertical Sealing Hubs - 25% Fill

Vertical Sealing Hubs - 25% Fill
Sealing hubs join pieces of conduit to unthreaded openings in boxes, enclosures, or other electrical devices and can be used in a vertical orientation only. They have a 25% fill and conductors should not exceed this amount of space within the fittings so they can be sealed properly. Sealing fittings hold a seal around wire within RMC and IMC conduit to minimize the passage of gases and vapors, prevent the passage of flames from one electrical installation to another, restrict explosions to the sealed-off enclosure, and prevent pressure from piling up in the conduit system. They’re suitable for use in hazardous locations where flammable gases, vapors, powdered metals, or dust is present.

Male to Female Threaded Ends

Loading...
Note: Product availability is real-time basis and adjusted continuously. The product will be reserved for you when you complete your order.
Back to Top